A novel device for intracolonoscopy cleansing of inadequately prepared colonoscopy patients: a feasibility study.
2019
Abstract Background The importance of high quality preprocedural bowel preparation is widely acknowledged, but suboptimal bowel cleansing still occurs in up to 20 % of all colonoscopy patients. The aim of this study was to evaluate the performance of a novel intraprocedural cleaning device for cleaning poorly prepared colons. Methods This multicenter feasibility study included patients aged 18 – 75 years who were referred for colonoscopy. Intraprocedural cleaning was performed in patients after a limited preprocedural bowel preparation regimen (2 days of dietary restrictions and 2 × 10 mg bisacodyl). The primary outcome was the proportion of adequately prepared patients (Boston Bowel Prepar…
Intraluminal Doppler-Sonography: Analysis and “in Vitro Test” of a New Device
1992
In treating patients with coronary heart disease it’ s necessary first to determine what influence the stenose has on the coronary blood flow. This is a prerequisite for any invasive treatment method. Coronary angiography explosures are only partially useful in attaining a functional evaluation of the haemodynamic stenoses.
Photovoltaic plant array reconfiguration: Design of a new device
2014
An efficient strategy to improve unequally irradiated PV plants performances is based on the reconfiguration of the connections between the modules. In this paper, an algorithm, for this purpose conceived, is presented. Moreover, the design, realization and finally also the set up of a new reconfiguration system device is fully shown and discussed. The algorithm conceived simulates several possible series-parallel connections under varying irradiation conditions, and determines the optimal modules connection in order to get the maximum output power. In this way, the reconfiguration system may set up the reconfiguration strategy. The reconfiguration system prototype set up, basically consist…
PIPERADE: A double Penning trap for mass separation and mass spectrometry at DESIR/SPIRAL2
2021
International audience; A double Penning trap is being commissioned at CENBG Bordeaux for the future DESIR/SPIRAL2 facility of GANIL. The setup is designed to perform both high-resolution mass separation of the ion beam for trap-assisted spectroscopy, and high-accuracy mass spectrometry of short-lived nuclides. In this paper, the technical details of the new device are described. First offline tests with the purification trap are also presented, showing a mass resolving power of about 105.
JYFLTRAP: a cylindrical Penning trap for isobaric beam purification at IGISOL
2004
Abstract A Penning trap has been installed for isobaric beam purification at the IGISOL-facility at the University of Jyvaskyla. In this paper, the technical details of this new device together with results of the first tests are presented. The mass resolving power, depending on the excitation parameters and the ion species, can be as high as 145 000 and the total transmission has been determined to be 17%. In addition, it is shown that with this experimental setup it is possible to measure atomic masses up to A=120 with accuracies of approximately 50 keV .
SU-E-T-218: Octavius 4D: Commissioning and Clinical Implementation of a New Device for VMAT Verifications
2013
Purpose: To commission a new device for pre‐treatment patient specific verification of VMAT plans, which is capable of reconstructing 3D dose with high resolution. Methods: Octavius 4D system (PTW) consists of an ion chamber array embedded in a cylindrical phantom which, assisted by an inclinometer, rotates synchronously with the gantry. For VMAT plans, it measures planar dose distributions as a function of gantry angle in order to compute the resulting 3D dose distribution. There are two options for the ion chamber array: Octavius 729 (general purpose) and Octavius 1000 SRS (small field size, high resolution). We have used three linacs: two Varian Clinac iX and one TrueBeam with MLC HD 120…
Effect of High-Frequency Oscillations on Cough Peak Flows Generated by Mechanical In-Exsufflation in Medically Stable Subjects With Amyotrophic Later…
2016
BACKGROUND: Mechanically assisted coughing with mechanical in-exsufflation (MI-E) is recommended for noninvasive management of respiratory secretions in amyotrophic lateral sclerosis (ALS). To improve the effectiveness of the technique, a new device combining MI-E with high-frequency oscillations (HFO) has been developed. This work aimed to assess the effect of HFO on the cough peak flow generated by MI-E in medically stable subjects with ALS. METHODS: This was a prospective study that included subjects with ALS in a medically stable condition. Cough peak flow generated by MI-E was measured in 4 situations: without HFO, with HFO during insufflation, with HFO during exsufflation, and with HF…
Effects of the novel polymer gel LeGoo on human internal thoracic arteries.
2011
Purpose Established hemostatic devices can injure vessel wall integrity. LeGoo (Pluromed, Woburn, MA), a novel poloxamer gel with reverse thermosensitive properties, is a new device for temporary occlusion of blood vessels. The present study investigated the effects of LeGoo on vascular function and morphology. Description The distal end of the human internal thoracic artery was used to assess vascular function of LeGoo-applied segments in organ bath experiments and by scanning electron microscopy. Evaluation After LeGoo application, both maximal contractile responses to noradrenaline and endothelium-dependent relaxant responses to acetylcholine were significantly reduced. Scanning electron…
A new device for emergency airway management: the EasyTube.
2003
Mitral valve therapy still surgical?
2015
Mitral regurgitation (MR) is the second most common valvular heart disease after aortic valve stenosis. With increased understanding of the heterogenic pathophysiology of MR, cardiac surgeons have developed various techniques that increase the likelihood of successful mitral valve repair (MVR). Nowadays, a rate of repair >90% may be reached in some mitral valve reference centres. In recent years, the introduction of transcatheter mitral valve intervention techniques has opened up new frontiers in mitral therapy, specifically in patients at high risk for standard surgery. Current percutaneous technologies for MVR have been developed on the basis of some of the surgical principles. Based on c…